Release notes
What changed in each Prose release. Prose updates itself the next time you open it, so the
newest version below is the one you are running.
New
- ✨New Attached Canopies C&C module for ASCE 7-16 and ASCE 7-22
Fixes
- Fixed issue preventing adding Snow drift cases when the roof slope is exactly 0°
- Corrected ASCE 7-16 hip and gable GCp, which began interpolating at the wrong minimum effective area
- Corrected monoslope roof pressures at exactly 3° and 10°, which used the neighboring figure
- Corrected roof pressures on buildings over 60 ft with 7° to 10° slopes, which used the low-slope table instead of the sloped-roof figures
- Corrected ASCE 7-10 roof pressures over 60 ft above 10°, which used the low-rise monoslope figure instead of the sloped-roof figure the tall-building figure requires
- Corrected hip roof corner zone GCp on 7° to 20° slopes, which used the wind-normal width B instead of the least horizontal dimension
- Corrected the reduced edge and corner zone width a, applied on 8° to 10° roofs and at exactly 300 ft of width where it does not apply
- Corrected open roof CN zones, sized from the effective wind area instead of the edge distance a
- Corrected C&C wall suction on buildings over 60 ft, which used qz at the zone elevation instead of qh
- Corrected MWFRS roof overhang pressures, which added 0.8 to the top-surface Cp instead of subtracting it and included internal pressure
- Corrected MWFRS wall pressures and line loads per level: the lowest tributary now starts at the base, and each tributary integrates its actual remaining height
- Corrected MWFRS open roof results when γ=0 and γ=180 land on different figures, which previously failed instead of reporting both
- Corrected which open roof figure MWFRS uses for each wind direction, h/L, and slope, including the low-slope monoslope exception
- Corrected ASCE 7-22 C&C overhang pressures in roof edge zones, which used the corner wall GCp instead of the interior wall GCp
- Corrected the ASCE 7-10 Exposure B Kz minimum, which was not applied to C&C pressures below 30 ft
- Corrected the ASCE 7-10 air density table behind Ke, whose values above 6,000 ft were listed against the wrong elevations
- Corrected the Kzt exemptions, which now apply below rather than at H/L of 0.2, hill height 15 ft in Exposure C and D, and 60 ft in Exposure B
- Velocity pressures above the gradient height no longer assume Kz = 2.01; they now require an engineer-approved value for that exposure and code edition
Other changes
- Clarified when the minimum ±16 psf C&C design pressure controls, while preserving the calculated pressure for review
- Roof pressure tables now appear in the MWFRS roof section
- Values you type are now saved when you leave the field instead of while you are still typing
- Added notes on roof inputs explaining when open building figures apply and which wall zone overhangs use
- Parapet roof zone choices are now limited to the zones that apply, and calculations now stop with a clear message when a roof shape or building height falls outside what the code covers
- Corrected wind code references, equations, and figure labels shown in summaries and reports
- Existing wind projects may show updated pressures when reopened, so re-check your wind results
Fixes
- Fixed ASCE 7-22 windward snow drift widths being cut short once the drift height reached the clear height
- Fixed ASCE 7-22 minimum roof snow load and rain-on-snow surcharge ignoring the structure Risk Category
- Corrected the snow drift width equations shown in ASCE 7-22 reports
Other changes
- Existing ASCE 7-22 projects in Risk Category I, III, or IV may show updated minimum roof snow loads and rain-on-snow surcharges when reopened
New
- Added a navigable outline to wind, snow, and seismic summaries
Fixes
- Fixed sloped-roof MWFRS calculations failing when h/L exceeds 1.0
- Fixed active wind summaries occasionally showing outdated results
Other changes
- Improved wind result tables across on-screen summaries and PDF reports
- Improved PDF table wrapping, repeated headings, equations, and wind figures
Fixes
- Fixed C&C Zone 1' roof pressures for effective areas between 10 and 100 square feet
- Fixed C&C hip roof pressures ignoring the structure width B you entered
- Fixed C&C structure width B entry overwriting the parapet height
- Fixed C&C structure width B entry rejecting buildings wider than 90 feet
- Fixed C&C parapet height entry missing on flat roofs with slopes of 7 degrees or less
Other changes
- Corrected C&C parapet height label on roof inputs
- Existing hip roof projects with slopes between 7 and 20 degrees may show updated pressures when reopened; re-check the structure width B and parapet height values
New
- Added support for choosing between multiple organizations when setting report company info
- New projects now automatically pick up your organization's default company info and logo
Fixes
- Fixed PDF reports occasionally hanging indefinitely when a company logo failed to load
- Fixed the report cover page missing the company logo and header
- Fixed clicking a link in a report PDF navigating away from the app
- Fixed an onboarding tour overlay blocking the Save Project button on first load
- Fixed older projects losing their live organization address after a recent update
Other changes
- Bundled demo projects now ship with sample company info and a logo out of the box
- Added a confirmation prompt before resetting company info back to organization defaults
- Shared project files now show the same company info and logo for every recipient, no matter who opens them
New
- Added the ability to put your company's name and details on reports
- Added your company logo to PDF reports
Fixes
- Fixed Components & Cladding summary tables not showing which region each result belongs to
Other changes
- Improved the look and behavior of module controls
- Refreshed the main screen with a cleaner background
Fixes
- Fixed partially enclosed wind buildings showing open-roof options
Fixes
- Corrected minimum roof load labels so overhang cases are clearly identified
- Corrected roof C&C results so excluded overhangs show zero pressure and coefficient values
- Added validation to prevent zero-area open-roof C&C calculations
- Prevented zero-length topographic inputs from causing wind factor calculation failures
Fixes
- Fixed incorrect wall and parapet wind pressures for east/west wind on buildings with a single exposure category
- Fixed incorrect Components & Cladding wind pressures on certain hip roof Zone 3 configurations (ASCE 7-16)
- Fixed wind summary always showing "Enclosed" for partially enclosed and open buildings
- Fixed open-building parallel-to-ridge cells in the wind summary showing pressure coefficients instead of design pressures
- Added missing "psf" units on flat-roof and open-building wind summary pressure cells
Fixes
- Fixed the assembly name being lost when editing materials in the Dead Load module
New
- Added an Example Retail Project demo, available via the Show Demos toggle on the home screen
Fixes
- Home screen now opens to your recent files instead of the demos view when files exist
New
- Added an Example Multifamily demo project, available via the Show Demos toggle on the home screen
Fixes
- Fixed incorrect units shown for rain load zones
- Removed incorrect "psf" unit on h/L in sloping roof Cp tables
- Fixed ASCE Hazard Tool sometimes failing to pre-fill location data
- Fixed minor text issues on the Recent Files list
Other changes
- Improved load module performance
- Project address, engineer, and EOR now auto-fill into new structures
- Numbered duplicate module types in the sidebar (e.g., Wind 1, Wind 2)
- Hid topographic factor tables in wind summaries when not used
- Allowed finer decimal precision on drainage system inputs
- Mean roof height now rounds to 2 decimal places in reports
- Improved table and figure alignment in rain and wind reports
- Seismic response spectrum is now always visible, with a wrapped criteria table for readability
New
- Added ASCE 7-22 support for Wind Load Modules
- Added ASCE 7-22 support for Rain Load Modules
- Added ability to zoom the App in and out with Ctrl + +/- and Ctrl + Mouse Wheel
Fixes
- Fixed bugs in seismic levels when building had no levels or top elevation was zero
- Fixed broken image in Components & Cladding for Flat Roofs
- Fixed broken Drift calculations for all code years
- Fixed snow minimum roof load calculation not saving correctly
- Fixed ASCE Hazard Tool not opening correctly
Other changes
- Improved sign-in session reliability and license server feedback
- Improved styling on the home screen
New
- Added ASCE 7-22 support for Seismic Load Module
- Added automatic seismic system translation when switching between building code editions
- Added seismic design criteria migration when changing building codes
- Added confirmation dialog when changing building code to prevent accidental data loss
Fixes
- Fixed seismic site coefficient tables for ASCE 7-16 (Fa and Fv values corrected per Supplements 1 and 3)
- Fixed Seismic Design Category determination for high-seismic sites (S1 ≥ 0.75)
- Fixed seismic response coefficient equation display
Other changes
- Improved seismic module interface with updated layout and controls
Fixes
- Fixed sign-in via deep link failing when multiple windows are open
New
- Added ASCE 7-22 support for Snow Load Module
- Added ASCE Hazard Tool integration for looking up ground snow loads and other site-specific data
- Added thermal condition support for heated structures with roof R-value input (ASCE 7-22 Table 7.3-3)
- Added code references (sections, equations, figures, tables) to all snow load calculation forms
- Added mathematical notation with tooltips to snow load table headers
- Added Winter Wind Map modal for W2 parameter visualization (ASCE 7-22)
Fixes
- Fixed ASCE 7 snow load code references across all editions (7-10, 7-16, 7-22)
- Added proactive authentication token refresh before session expiry
New
- Added partial support for IBC 2024 building code
- Added ASCE 7-22 support for Live Load Module
- Added ASCE 7-22 support for Dead Load Module
- Added edition-specific live load tables for ASCE 7-10, 7-16, and 7-22
- Added GCp reduction footnote for walls C&C when 10% reduction is applied for roofs ≤10° slope
- Added validation to prevent parapet elevations below the highest building level
Fixes
- Fixed project summary not displaying live load modules
- Fixed broken tooltips in snow load calculations
- Fixed GCp reduction footnote display and code references in wind C&C summary
Other changes
- Added warnings when opening structures with unsupported modules for the selected building code
Fixes
- Fixed application startup issues
New
- Added success notifications for region creation and deletion in wind directional views
Fixes
- Fixed wind C&C wall pressure calculations not accounting for actual roof slope
- Fixed toast notifications not displaying correctly in wind module
New
- Added floating seat license management for multi-device usage
- Added ability to use the same material multiple times in an assembly
- Added "Update & Restart" option for application updates
- Added exposure factor dropdown selection in snow load calculations
- Added option to include minimum snow load design case
- Added success notification when saving assemblies
Fixes
- Fixed license status not displaying correctly after sign-in
- Fixed application startup failures on slow connections
- Fixed backup tracking for moved or renamed project files
Other changes
- Improved application startup reliability and stability
- Improved project loading with more detailed error messages
- Parapets section now only displays when applicable
- Wind MWFRS reports now exclude parapet sections for buildings without parapets
New
- Added periodic project path validation for Recent Projects
Fixes
- Fixed handling of undefined file paths in Recent Projects list
New
- Improved Recent Projects UX with validation and stale entry handling
- Enhanced loading indicators with project closing state
- Improved open roof table zone ordering
Fixes
- Fixed issues with design pressures value not displaying correctly in Components & Cladding Parapets
- Fixed Cn Values being flipped in snow load calculations
- Fixed walls ≤60ft C&C equation calculations
New
- Added support for Email/Password Login inside the app
Fixes
- Fixed display issues in Sloped Roof Snow Load calculations
Other changes
- Improved Wind MWFRS sloped roof calculations
New
- Added Bookmarks to the Calc Book PDF
New
- Added zoomable image viewing
- Added structure duplication from the sidebar, including nested load modules
- Set rain loads static head defaults to 2"
- Added standard effective areas for Wind C&C and allowed custom ones
Fixes
- Updated Building Code label to "Structural Design Loads per"
- Fixed Wind MWFRS formatting issues
New
- Added Support links to the sidebar
Fixes
- Fixed issues with material import
Fixes
- Fixed issues with the MWFRS Summary display
Fixes
- Fixed issues with stale Equation References in Wind Module summaries
Fixes
- Minor bug fixes and performance improvements
Fixes
- Minor bug fixes in the Code Reference links across the app
New
- Fixed invalid Code References in Snow and Rain Modules
Fixes
- Increases the project load timeout to 30 seconds
Fixes
- Fixed issues in the Wind Module C&C image display
Fixes
- Fixed temp files not being deleted after use
New
- Added bulk edit functionality for materials
Other changes
- Improved app startup time
New
- Added a default assembly when creating a Dead Load Module
New
- Added API link to the sidebar
Fixes
- Minor bug fixes in the user interface
Other changes
- Improved overall performance
New
- Added email notifications for completed tasks
Fixes
- Fixed login issues for new users
Other changes
- Added loading indicators for the Materials Import operations
New
- Added support for bulk importing materials